Keithley 2400 error code 601. This manual applies to: 2400, 2410 C, 2420, 2420 C .
Keithley 2400 error code 601 I am using a GPIB-USB-HS and Labview 2010, windows XP. 1, pin 2. 三、故障判定:仪器开机屏幕显示 报错信息601,测试仪器前后面板基本的电压电流输出功能正常,通讯正常,检测电流指标微安级别存在超差 。 May 14, 2016 · Background: * Keithley 2400 with fw C19 upgraded to C33 * The EEPROMs on the digital board reads: 2400-803C11 ODD and 2400-804C11 EVEN (I assume that they were programmed with C11 initially) * Used an USB-to-RS232 cable for communication. SourceMeter. 2) the buadrate is not the same on pc and keithley (or another serial line parameter that I would like to see on the frontpanel of the initialize) Jul 25, 2022 · Author Topic: Keithley 2400 Error: No Com Link (Read 1890 times) 0 Members and 1 Guest are viewing this topic. G / February 2006 A GREATER MEASURE OF CONFIDENCE www. . 维修案例: 吉时利2400源表开机报错维修案例. Oct 31, 2023 · 吉时利数字源表系列特别适用于需要精密电压源和电流源驱动,同时进行电流与电压测量的测试应用。所有源表都提供精密的 Feb 6, 2018 · Hello guys, I have a problem that I have been scratching my head with for a week. Try to do more reads of less length, less then 112 readings, say 64 readings each time. G / February 2006 A GREATER MEASURE OF CONFIDENCE 2400-902-01. I'm having trouble getting Keithley 2400 to communicate with LabView. com/Soldering-StationsNew TL866-3G EPROM multitool ht Jan 8, 2020 · Re: help with repairs Keithley 2400 « Reply #17 on: August 28, 2022, 11:40:06 pm » I didn't want to start another thread, but wanted to document what it took to fix my Keithley 2420. Flash wizard communicated correctly with 2400. Aug 25, 2010 · http://www. It still show the same errors. Thanks. It's soldered in with tabs (manual implies it's socketed) -- it's hard to find a replacement nearby Did you get to replace the battery? Apr 23, 2021 · We have a Keithley 2400 here in our university lab that briefly shows Error 601 at startup The lithium battery is dead (0. I have a Keithley 2400 sourcemeter, I want to control it with my computer using Labview. welectron. If you are unsure about the applicability of a replacement component, call a Keithley Instruments office for information. I don't have access to a keithley at the moment but this is easy to do. warrants this product to be free from defects in material and workmanship for a period of 1 year from date of shipment. This manual applies to: 2400, 2410 C, 2420, 2420 C May 29, 2024 · 吉时利2400源表(Keithley 2400 SourceMeter)是一款高性能的源测量单元(SMU), 发表于 05-23 17:06 • 981 次阅读 数字源 表 的常见 故障 和 维修 方法 Sep 2, 2023 · Having a random timeout problem with Keithley 2400 that is driving me nuts and became a challenge. check the voltage of the 3V lithium battery that supplies the reading-buffer RAM. com Model 2400 SourceMeter® Service Manual 2400-902-01 Rev. warrants the following items for 90 days from the date of ship-ment: probes, cables, rechargeable batteries, diskettes, and documentation Jun 21, 2022 · Upon reinstallation, LABView 2017 and Keithley 2400 work with no issues until I start a run, at which point the Keithley 2400 displays an Error:ID Code = -101. ×. its probably dead. Newbie; Posts: 2; Country: Feb 15, 2006 · Keithley 源测量单元 2400, 2410 C, 2420, 2420 C, 2425, 2425 C, 2430, 2440 Please Login/Register to interact with the search results. Feb 19, 2010 · What driver are you using? The error message looks like an IVI error!. cuongyd. qxp 8/11/2006 1:24 PM Page 1. Can you please tell me where you bought the battery and a part number. Jul 1, 2014 · Hey guys. I already have Keithley 6220 running in the setup, so I tried just copying and pasting the code for it (not written by me, but it works just fine) and just changing the GPIB address, but that didn't work. 5. com/products/semiconductor/autotestsys/?mn=2400 How To Restore Factory Defaults - Keithley Instruments Model 2400 Series Keithley Instruments, Inc. I kept getting Feb 15, 2006 · This manual provides verification, calibration, routine maintenance, troubleshooting, and disassembly information. keithley. Login. 分享吉时利2400输. Nov 10, 2011 · A few possible errors: 1) the serial cable is wrong, you need "straight through"connection pin 1. Jan 13, 2018 · nothing serious. In the experiment the constant voltage is sourced, and I only read current. You should use the native LabVIEW driver and not the IVI driver. This goes away when I activate sourcemeter, but this freezes any runtime being recorded and I get no data. 吉时利2400维修案例一、仪器型号:吉时利2400源表二、故障现象:仪器开机通电后出现电压源20v、200v档位输出异常。 三、分析、测试与判断:电压源输出异常,在20V档位实际输出-177V,但测量显 吉时利2400源表采用了先进的 数字合成技术 ,能够生成高精度的电压、电流等电学参数。这使得它能够为实验提供更为精确的测量结果。吉时利2400源表错误代码601表示控制器无法与外部设备进行通信。以下是对此错误代码的可能原因及解决方案的详细分析: Jun 11, 2024 · 吉时利2400源表采用了先进的数字合成技术,能够生成高精度的电压、电流等电学参数。这使得它能够为实验提供更为精确的测量结果。吉时利2400源表错误代码601表示控制器无法与外部设备进行通信。以下是对此错误代码的可能原因及解决方案的详细分析: Sep 2, 2020 · Other Support Options Ask the NI Community. 二、仪器外观检测:正常 . 一、报修故障: 开机报错601. Search the NI Community for a solution; Request Support from an Engineer Jan 23, 2011 · Hello I am trying to acquire data from keithley 2400 using labview 9, NI VISA 4. 手册 Sep 13, 2023 · I need to replace the battery in my Keithley 2400. View and Download Keithley 2400 service manual online. Collaborate with other users in our discussion forums. warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable batteries, diskettes, and documentation. * Upgraded with Flash Wizard C12 (from Keithley homepage). Keithley Instruments, Inc. 2V) and it is soldered to the board but I will replace it. 3 etc. 2, pin 3. Change the read into a for loop of reads and test it. 2400 measuring instruments pdf manual download. I have done the following steps: 1- I used the Labview Instrument drivers but unfortunately executing any labview driver result Sep 17, 2015 · Series 2400 SourceMeter User's Manual. To clean an instrument, use a damp cloth or mild, water-based cleaner. An assertion ending with a question mark is a brain fart. ECA 41379 Sep 20, 2010 · I downloaded NI-VISA latest version and still the problem exists. Thanks steve Sep 5, 2022 · $2 PCBs & NEW discounted colors → https://jlcpcb. com/IYBFinest soldering stations https://www. I cannot find the Keithley BA-44 battery mentioned in the manual. Also, when we switch on the instrument, for second, we get "Error: ID Code-601" on display. Apr 10, 2024 · 吉时利2400是一种广泛应用于工业自动化领域的plc控制器。在使用过程中,有时会遇到报错601的情况。该报错表示控制器无法与外部设备进行通信。 Keithley 2400 系列(2410,2420,2430)--常见问题集 美佳特 吉时利数字源表 系列特别适用于需要精密电压源和电流源驱动,同时进行电流与电压测量的测试应用。 Keithley Instruments, Inc. Nov 28, 2016 · I think the problem is not in the VISA buffering but in the keithley. I used the attached "Keithley www. However I have two questions: 1-are the calibration constants lost and the unit definitely needs calibration now? Jan 9, 2015 · No, its not exposed to sunlight, also not getting heated at all! We think there might be a problem with one of the instrument component. 1, and serial RS 232 interface. Dieses Handbuch bezieht sich auf: 2401, 2400, 2420, 2440 0, 2410. qpkzlgvmpewppzhjutfsyetsmkfabkoxumxhxlaklbtzscdigrvaiwbxmqogs